Solaredge - Activate Modbus TCP
The following guide describes how to configure the Modbus TCP
settings for SolarEdge inverters and how to test the connection.
Prerequisites
- Network connectivity (Ethernet or WiFi)
- Physical access to inverter
- Web browser
- Mobile device with camera
Configuration Process
Physical Access Setup
- Locate the
on/off
switch on the inverter- Usually has a red cap
- Typically found near the bottom left of the inverter
- Push the switch to the left (
P
) for 1 second - Release the switch
Network Connection
- Locate the
QR code
on the right side of the inverter - Scan the
QR code
using your phone's camera - Connect to the WiFi network indicated by the code
- Note: You may receive a notification about the network lacking internet access
- If this occurs, select "Use network anyways"
Modbus Configuration
- Open a web browser
- Navigate to
http://172.16.0.1/
- Find the "Communication Settings" section
- Enable the
Modbus TCP
option - Note the port number shown
- Usually
502
or1502
- Write down, you'll need this for future reference
- Usually
Important Notes
- Document the port number for future use
- Maintain network connectivity during configuration
- Ensure proper physical access to inverter switches
Troubleshooting
Connection Issues
If unable to connect:
- Verify
QR code
scan was successful - Check WiFi connection status
- Confirm correct
IP
address entry
Configuration Problems
If settings don't apply:
- Refresh browser page
- Verify network connection
- Try alternative browser
Testing connectivity (advanced)
After enabling Modbus TCP on your SolarEdge inverter, it's important to verify that the connection is working properly. You can follow our testing guide to confirm the connection. For SolarEdge inverters, try both port 502 and 1502, as the port number can vary between models and firmware versions. The Unit ID is typically set to 1. Make sure to document both the working port number and Unit ID for future reference, as you'll need these for any monitoring setup.
Sources
- Sourceful Community
- SolarEdge Modbus TCP Configuration Guide